Our Calibration laboratory components...

-Pressure source PPS1100 HP700 - Manufactured in Switzerland
- INTI calibration certificate.
- Range 0 / 10.000 Psi resolution 0,0014 Psi (0,1 millibar)
- Total accuracy ±0.08% 0 a 50°C f.s.v. including linearity, repeatability, temperature, hysteresis and screen resolution combined errors
- Units: Bar, Psi, kPA, mWC, etc
- Sample rate 2/second, memory 900 positions.
- Oil type HLP-22-BP FDA & MSP approved.
- LEAK function over time up to 900 minutes
- LIN function for linearity analysis.
- PC communication via K101 cable and Logger system for direct measures with resolution 0.0001 Psi. with plotting and data analysis.

-Transducer simulator # 999084-999461
- INTI & NIST calibration certificate.
- Accuracy ± 0,1% 0 to 50 °C full scale
- Output 1.5 mV/V - 2.0 mV/V - 2.5 mV/V - 3.0 mV/V - 3.33 mV/V
- Fixed points 0% - 20% - 40% - 60% - 80% - 100%
- Variable scale 0 - 100% continuous

-Process controller DPC535.1.1.1.5-604-ESP-Z-2003
- 22 thermocouple types B-E-J-N-R-S-T-W-W5-Platino II.
- 6 RTD types: DIN - JIS - SAMA. -- 2 DC current: 4-20 mA - 0-20 mA.
- 2 DC voltage: 0-5 VDC - 1-5 VDC
- 5 DC millivolts: 0-10 mV - 0-30 mV - 0-60 mV - 0-100 mV - -25 mV a +25 mV
- Strain gauge 350 ohm.
- Auxiliary power supply 24 VDC ±0.5%.
- Sample rate 100 milliseconds. - Display refresh 200 milliseconds

-Smartlink software for HART with VIATOR mdm #901541-ENG-Z-2006
- Smartlink software for HART up to 199 variables.
- VIATOR RS-232 HART modem with alligators clips.

-Portable bench multimeter with RS-232 link 60.000 counts
- INTI calibration certificate
- Graphic display 5+5 digits with graphic bar and two simultaneous variables
- Voltage: resolution 1 µV accuracy 0,02%
- Current: resolution 0,01µA accuracy 0,1%
- Resistance: resolution 0,01 Ohm accuracy 0,09%
- Serial/infrared accuracy 1% or 1 digit.
- Microvolt precision 1% or 1 digit

-HP Agilent bench multimeter 34401A 6 ½ digit 1.200.000 counts
- INTI calibration certificate
- Voltage: resolution 0,01µV accuracy 0,0015%
- Current: resolution 0,01µA accuracy 0,0015%
- Resistance: resolution 0,0001 Ohm accuracy 0,002%
- Communication serial / GPIB

-Multifunction calibrator PROVA
- INTI calibration certificate
- 4-20 mA / 0-20mA / 0-24mA accuracy 0,025%
- 0-12 Vdc resolution 1 millivolt accuracy 0,05%
- Frequency 2-50.000 Hz accuracy 0,005%
- Thermocouples K, J, E, T direct simulation accuracy 0,05%

-Dry Block RE-SIS-TEN.com
- Range 20°C a 400°C
- Refrigeration circuit by air
- INTI calibration certificate

-Temperature sensor
- RTD PT-100 grade 1/10 DIN
- Accuracy 0,01°C
- INTI calibration certificate

-PT100 calibrator Presical PJ6522B1
- INTI calibration certificate
- Sample rating 2 / second
- Measuring range -200°C / +850°C accuracy 0,1% +0,1°C
- Measuring current <0,4 mA
- Simulation function by EN 61010-2-031
- Resolution 0,1°C accuracy 0,1% +0,1°C